Przeglądanie stron 24
Monitoring Services PIC
JUNOS 5.6 and laterSoftware release
Active traffic monitoring
Power requirement: 0.19 A @ 48 V (9 W)
Monitors IPv4 packets
Support for collecting and exporting cflowd records
Description
Monitors up to 100,000 packets per second
Support for MTUs up to 4474 bytes for SONET interfaces
Hardware features
For a list of the software features available for services PICs, see the JUNOS Services Interfaces
Configuration Guide.
Load distribution across multiple PICs
cflowd version 5 support
Provides start and end times of each export
Supports firewall filtering and filter-based forwarding (FBF)
Encapsulations:
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
Software features
DB-9 diagnostic serial console portCables and connectors
Status LED, one tricolor:
OffPIC is offline and it is safe to remove it from the chassis
GreenPIC is operating normally
AmberPIC is initializing
RedPIC has an error or failure and no further harm can be done by removing it from
the chassis
Application LED, one tricolor:
OffFlow collector is not running
GreenFlow collector is running under acceptable load
AmberFlow collector is overloaded
LEDs